Mfg Part Number: TT1 10835 | Alternate P/N: TT110835 | Manufacturer: Transformer Technicians Inc |
NSN : 5950-00-279-4018 | Item Name : transformer power | CAGE Code : 96253 |
FSC : 5950 Coils and Transformers |
Thank you for choosing Industrial Part Numbers to source your needed NSN components. We have the Helicopter Search A part, listed with the part number TT1 10835, available for immediate purchase through our website today. This item was manufactured by Transformer Technicians Inc and is under the NSN 5950-00-279-4018. If you are interested in a quotation for TT1 10835 component, or any other product listed on our website, we invite you to use our Instant RFQ service. To begin, simply fill out the RFQ form for TT1 10835 found on this page with as much information as possible before clicking submit. With account managers available for customers 24/7, you will receive a personalized solution in just 15 minutes or less.
Whether you are looking for NSN parts associated with the CAGE Code 96253 or others, Industrial Part Numbers has you covered. Our expansive NSN catalog includes thousands of high-quality components like 5950-00-279-4018 from top manufacturers, such as Transformer Technicians Inc. We offer customers access to our vast inventory with rapid lead-times and competitive pricing. Additionally, if you face AOG requirements, you can depend on our same-day and next-day shipping options on select in-stock items. Get started on the purchasing process with an RFQ and see why many customers choose Industrial Part Numbers as their strategic sourcing partner.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-279-4018 Item Description: Transformer Power | 5950 | 002794018 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TT1 10835 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.940 INCHES MAXIMUM3.940 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.030 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.030 INCHES MAXIMUM SINGLE MOUNTIN |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.350 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.350 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.410 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.410 INCHES MAXIMUM SINGLE MOUNTIN |
ABMK | OVERALL WIDTH | 2.120 INCHES MAXIMUM2.120 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYEWYE-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.940 INCHES MAXIMUM3.940 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT9 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 185.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY130.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY130.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 9 SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 27 STANDOFF, SOLDER LUG |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.